Okuma Alarm-P 0958 Pitch compensation data file read


Okuma Alarm-P 0958 Pitch compensation data file read
For the NC provided with the function of ball screw pitch error compensation or Inductosyn pitch error compensation, the pitch error compensation data file is not found in the memory at the time of power supply or has an unspecified data size.

Object
None

Character-string
None

Code
FFFFFFFF->No compensation data file is found.
Other codes->The compensation data file has a wrong data size.

Probable Faulty Locations
Pitch error compensation data file

Operation Example
The operator has mistakenly deleted the pitch error compensation data file in the memory.

Measures to Take
Reinstall the control software.

Related Specifications
Pitch error compensation specification Instruction Manuals to Be Referenced.
Ball screw pitch error compensation->Special Functions Manual
No. 2 Inductosyn pitch error compensation->Instruction manual for high-precision lathe / Operation manual for automatic setting of Inductosyn pitch error compensation values

Okuma Alarm-P 0958 Pitch compensation data file read