Okuma Alarm-P 0889 MCS Axis change control error


Okuma Alarm-P 0889 MCS Axis change control error
Axis control did not operate correctly.
(This alarm is not the one occurred in the MCS.)

Object
Axis name or none (spindle)

Character-string
None

Code
The MCS has not been reset within 110 sec.
The parameter pair number agree signal or the control ready signal has not been turned on within 210 sec.
The max. APA value of a separated encoder has not been received within 310 sec. In-position amount or zero offset amount could not be changed within 610 sec.
After the occurrence of an alarm, in-position amount or zero offset amount could not be changed within 10 sec.

Probable Faulty Locations
* Faulty NCS controller for the PLC axis
* Software error

Okuma Alarm-P 0889 MCS Axis change control error