Okuma Alarm-D 4240 Tool life management No spare tool


Okuma Alarm-D 4240 Tool life management No spare tool
A tool group has run out of spare tools to be automatically indexed within the group.
Automatic index: When a tool reaches its life, a spare tool in the same tool group is automatically indexed.

Object
SYSTEM

Code
Hexadecimal number of the tool group having no spare tools

Measures to Take
After refreshing the tools in the group having no spare tool (by tool change or some other method), initialize the tool life management data of the group.
Initialize: The tool life management data is initialized in the following procedure:
Select the tool data setting mode and press the function key (ITEM) to display the tool life management screen. When the function key (INITIALIZE) is pressed, the message “Initialize OK (Y/N)!” appears.
Enter “Y” and press WRITE. (To cancel initialization, enter “N” and press WRITE.) Enter the tool group number to be initialized and press WRITE. To initialize all the tool groups, enter “0” and press WRITE.