Okuma Alarm-B 2677 Attachment change not possible


Okuma Alarm-B 2677 Attachment change not possible
It instructed when it was not possible to instruct in attachment data exchange. (M798,M799,M1061)

Object
SYSTEM

Code
1->There is no Attachment specification.
2->It instructed during the fixed cycle.
3->It instructed no Nose-R correction mode.
4->It instructed during the LAP cycle.
5->It instructed in the slope processing mode.
6->It instructed W axis control mode.
7->It instructed X axis mirror image coordinate system.
8->It instructed the translation, the rotational transfer, and in the COPY mode of coordinates.
9->It instructed while the tailstock and connecting the swinging stop.

Probable Faulty Locations
Program error

Measures to Take
The part that corresponds to the above-mentioned code is corrected.