Okuma Alarm-B 2668 X-axis mirror image coordinates impossible


Okuma Alarm-B 2668 X-axis mirror image coordinates impossible
X-axis mirror image coordinate system was not able to be selected.

Object
SYSTEM

Code
1-> X-axis mirror image coordinate instruction (G105) was executed while C-axis connection mode.
2-> X-axis mirror image coordinate instruction (G105) was executed while Y-axis mode.
3-> X-axis mirror image coordinate instruction (G105) was executed while Constant Surface mode.
4-> There is an axis movement instruction in the X-axis mirror image coordinate instruction block (G105).
5-> X-axis mirror image coordinate instruction (G105) was executed while Nose-R Compensation mode.

Measures to Take
The program instruction is defective.