Okuma Alarm-B 2533 Steady rest over interference pos.


Okuma Alarm-B 2533 Steady rest over interference pos.
Command for Steady-rests, Tail stock or W-axis to exceed the interference position.

Object
Axis

Character-string
None

Code
1-> Right steady-rests interference area (minimal distance).
2-> Left steady-rests interference area (maximum distance).
3-> Left steady-rests interference area (minimal distance).
4-> Right steady-rests interference area (maximum distance).

Probable Faulty Locations
1)Program error.
2)Interference range parameter is not correctly.

Measures to Take
1)Check the movement command of the axis.
2)Set the interference range parameter correctly.

Okuma Alarm-B 2533 Steady rest over interference pos.