Okuma Alarm-B 2409 TOOL LIFE CONTROL no spec.


Okuma Alarm-B 2409 TOOL LIFE CONTROL no spec.
Tool life management variables are designated although the control has no tool life management specification.
Tool group TG and tool offset group OG are designated.
Mnemonic G code or TLID is designated.

Object
SYSTEM

Code
1->Tool life management variables are designated in the left part of the expression.
2->Tool life control variables are designated in the right part of the expression.
5->Tool group TG and tool offset group OG are designated.
Mnemonic G code or TILD is designated.

Probable Faulty Locations
Program error
Program Example:

N010 TG=1 OG=1
N011 TLID

Measures to Take
Delete the tool life management commands TG, OG, and TLID from the program.

Okuma Alarm-B 2409 TOOL LIFE CONTROL no spec.