Code
1->A start command (M336) was issued with a machine alarm pending.
2->A start command (M336) was issued with the machine not linked.
3->The machine was in AUTO mode.
4->The machine was running.
5->The loader was not at the standby position.
6->The machine was temporarily suspended.
7->The machine was at a program or optional stop.
8->The machine was in SCHEDULE PROGRAM OPERATION mode.
9->The machine operation has been manually interrupted.
10->The main program has not been selected.
11->The cursor does not reside at the head of the main program.
12->Though a program selection number and a switch input program number were mismatches, cycle start from robot/loader was about to be done.
13->Remain the workpiece in the work-out bucket.
14->Front door or Side cover or Safety guard is open.
15->Start requirements did not satisfied within the preset time after a external start command.