Okuma Alarm-A 1531 Tool posture fluctuation reduction error


Okuma Alarm-A 1531 Tool posture fluctuation reduction error
Fatal abnormality to which processing was not able to be continued by Tool Posture Fluctuation Reduction function was detected.

Object
None

Character-string
None

Code
VVWWXXYZ:
VV: Module code
WW: Common processing code
XX: Peculiar code in each module
Y: Axis index
Z: Buffer manager error code
1=Error
2=Range of argument error
3=Effective number operation error
4=Empty numerical operation error
5=Data none
6=Write pointer overflow
7=Operation result error

Probable Faulty Locations
Faulty software

Related Specifications
Tool Posture Fluctuation Reduction

Okuma Alarm-A 1531 Tool posture fluctuation reduction error