Haas Parameter 295 SHTL SETTLE TIME – Haas Mill


Haas Parameter 295 SHTL SETTLE TIME – Haas Mill

Used on mills with an air driven shuttle. Allows settling time for the shuttle after it has moved toward the spindle and before a tool change is performed. It should be set to approximately half a second (500) on all mills with the air driven shuttle. This may vary. All other mills can be set to 0, since they are unaffected.