Haas Alarms

Haas Alarms – Haas Alarm Codes with description.

Haas Alarm 998 A FILE COULD NOT BE OPENED

Alarm: 998 A FILE COULD NOT BE OPENED Haas Alarm Description: A file on the current device could not be opened. Check the program number or name (check case).

Haas Alarm 997 TOO MANY FILES HAVE BEEN OPENED ON THE CURRENT DEVICE

Alarm: 997 TOO MANY FILES HAVE BEEN OPENED ON THE CURRENT DEVICE Haas Alarm Description: Device from which a program is running has reached maximum number of files which can…

Haas Alarm 996 TAIL STOCK MUST BE ZERO RETURNED – Haas Lathe

Alarm: 996 TAIL STOCK MUST BE ZERO RETURNED – Haas Lathe Haas Alarm Description: The hydraulic tail stock has been adjusted to a new position. The B-axis must be zero…

Haas Alarm 995 ERROR TOO LARGE – Haas Mill

Alarm: 995 ERROR TOO LARGE – Haas Mill Haas Alarm Description: Amplifier error too large. Difference between actual current and commanded current in amplifier is too great. This can be…

Haas Alarm 995 AMPLIFIER CURRENT ERROR TOO LARGE

Alarm: 995 AMPLIFIER CURRENT ERROR TOO LARGE Haas Alarm Description: Amplifier error too large. Difference between actual current and commanded current in amplifier is too great. This can be caused…

Haas Alarm 994 AMPLIFIER OVERLOAD

Alarm: 994 AMPLIFIER OVERLOAD Haas Alarm Description: The amplifier has detected a high load for an extended period of time. This can be caused by running the amplifier at more…

Haas Alarm 993 AMPLIFIER SHORT CIRCUIT

Alarm: 993 AMPLIFIER SHORT CIRCUIT Haas Alarm Description: This can be caused by any of the motor leads shorted to each other or shorted to the 320V return. This can…

Haas Alarm 992 AMPLIFIER OVER CURRENT

Alarm: 992 AMPLIFIER OVER CURRENT Haas Alarm Description: The amplifier has detected excessive current going to the motor. This can be caused by a stalled motor, a high motor load…

Haas Alarm 991 AMPLIFIER OVER TEMPERATURE

Alarm: 991 AMPLIFIER OVER TEMPERATURE Haas Alarm Description: The amplifier/vector drive temperature sensor indicates over 90°C near the power transistors. This can be caused by an extended overload condition of…

Haas Alarm 986 CALIBRATION FAILED

Alarm: 986 CALIBRATION FAILED Haas Alarm Description: The amplifier failed to self-calibrate within 30 sec. This can be caused by a faulty amplifier or a faulty Mocon.

Haas Alarm 985 DC BUS OV CHRG – Haas Mill

Alarm: 985 DC BUS OV CHRG – Haas Mill Haas Alarm Description: DC Bus over voltage during charge up. The DC bus monitor detected an improper charge-up. The DC bus…

Haas Alarm 984 VD SHORT CIRCUIT – Haas Mill

Alarm: 984 VD SHORT CIRCUIT – Haas Mill Haas Alarm Description: Shorted motor output. This can be caused by any of the motor leads shorted to each other or shorted…

Haas Alarm 983 VD OVER CURRENT – Haas Mill

Alarm: 983 VD OVER CURRENT – Haas Mill Haas Alarm Description: Vector Drive over current. The Vector Drive has detected excessive current going to the motor. This can be caused…

Haas Alarm 982 ZERO ANGLE MOVE

Alarm: 982 ZERO ANGLE MOVE Haas Alarm Description: This is caused by start and end point not coinciding and aligned with IJK. Set end point to the value of start…

Haas Alarm 976 PALLET POOL-INVALID PALLET

Alarm: 976 PALLET POOL-INVALID PALLET Haas Alarm Description: Requested pallet is not in pallet pool system. To correct problem: Change the p-code with the M50 command, select a pallet from…

Haas Alarm 971 FAILED LOAD

Alarm: 971 FAILED LOAD Haas Alarm Description: The on board device computer failed to load network drivers. This is from an invalid network setting. Cycle power. CNC should go into…

Haas Alarm 970 NO AXIS COMMANDED IN FEED CODE

Alarm: 970 NO AXIS COMMANDED IN FEED CODE Haas Alarm Description: There was an unknown command generated. If help is needed, please save your current program to disk and notify…

Haas Alarm 968 DOOR HOLD OVERRIDE ENGAGED

Alarm: 968 DOOR HOLD OVERRIDE ENGAGED Haas Alarm Description: Whenever Setting 51 is changed to On, Alarm 968 is added to alarm history along with the date and time of…

Haas Alarm 967 SKBIF COMMUNICATION FAULT

Alarm: 967 SKBIF COMMUNICATION FAULT Haas Alarm Description: A communication time out on the serial interface between the main control and the SKBIF has been detected. Any machine motion in…

Haas Alarm 965 TURRET CLAMP/UNCLAMP FAULT

Alarm: 965 TURRET CLAMP/UNCLAMP FAULT Haas Alarm Description: The turret did not clamp within the time specified in Parameter 62, or unclamp in the time specified in Parameter 63. Check…

Haas Alarm 964 TOOL TURRET ROTATE FAULT

Alarm: 964 TOOL TURRET ROTATE FAULT Haas Alarm Description: The turret did not rotate to the correct location within the time specified in Parameter 60. Check for obstructions that would…

Haas Alarm 963 UNABLE TO FNC FROM THIS DEVICE

Alarm: 963 UNABLE TO FNC FROM THIS DEVICE Haas Alarm Description: This device may not function from FNC. Change setting 134 the connection-type to an appropriate FNC device and try…

Haas Alarm 962 UNABLE TO RETRIEVE FILE INFORMATION

Alarm: 962 UNABLE TO RETRIEVE FILE INFORMATION Haas Alarm Description: File functions taking to long to process. Try reloading.

Haas Alarm 961 FLOPPY OFFSET NOT FOUND

Alarm: 961 FLOPPY OFFSET NOT FOUND Haas Alarm Description: This alarm is generated because FNC has lost the offset placemark it needs to correctly advance program. Try to reload program.

Haas Alarm 960 INDEXER SWITCH NOT FOUND IN TIME – Haas Mill

Alarm: 960 INDEXER SWITCH NOT FOUND IN TIME – Haas Mill Haas Alarm Description: The A-axis indexer down switch was not found within the allowed time specified by Parameter 659.

Haas Alarm 959 NON-INDEXER POSITION – Haas Mill

Alarm: 959 NON-INDEXER POSITION – Haas Mill Haas Alarm Description: The position commanded for the A-axis incremental indexer is a non-indexer position. The indexer positions are multiples of Parameter 647….

Haas Alarm 958 TOOL OFS WEAR HAS BEEN CHANGED

Alarm: 958 TOOL OFS WEAR HAS BEEN CHANGED Haas Alarm Description: Whenever the tool wear offsets are changed, alarm 958 will be added to the alarm history along with the…

Haas Alarm 957 APC-SWITCH FAULT – Haas Mill

Alarm: 957 APC-SWITCH FAULT – Haas Mill Haas Alarm Description: Illegal switch condition detected. The pallet clamp switch did not function correctly. Use M17 and M18 commands to verify the…

Haas Alarm 956 APC-LIFT FRAME UP TIMEOUT – Haas Mill

Alarm: 956 APC-LIFT FRAME UP TIMEOUT – Haas Mill Haas Alarm Description: The pallet changer was commanded to lift but the up position switch was not contacted before the timeout…

Haas Alarm 955 APC-INVALID PALLET CHANGER TYPE – Haas Mill

Alarm: 955 APC-INVALID PALLET CHANGER TYPE – Haas Mill Haas Alarm Description: Parameter 605 has an invalid pallet changer type. Model   Basic Value VF APC   2 MDC 500/EC-300…

Haas Alarm 954 APC-INCOMPLETE PALLET CHANGE – Haas Mill

Alarm: 954 APC-INCOMPLETE PALLET CHANGE – Haas Mill Haas Alarm Description: The last pallet change did not complete successfully or the mill has been initialized. Press Tool Changer Restore to…

Haas Alarm 953 APC-MISLOCATED PALLET CLAMP – Haas Mill

Alarm: 953 APC-MISLOCATED PALLET CLAMP – Haas Mill Haas Alarm Description: Pallet changer clamp plate is not in the expected position. The clamp plate must be unclamped while the pallet…

Haas Alarm 952 APC-MISLOCATED LIFT FRAME – Haas Mill

Alarm: 952 APC-MISLOCATED LIFT FRAME – Haas Mill Haas Alarm Description: Pallet changer lift frame is not in expected position. The lift frame was either down when expected to be…

Haas Alarm 951 APC-ILLEGAL SWITCH CONDITION, PALLET CLAMP – Haas Mill

Alarm: 951 APC-ILLEGAL SWITCH CONDITION, PALLET CLAMP – Haas Mill Haas Alarm Description: The pallet changer clamp switches indicate that the pallet changer is clamped and unclamped at the same…

Haas Alarm 950 APC-ILLEGAL SWITCH CONDITION, LIFT FRAME – Haas Mill

Alarm: 950 APC-ILLEGAL SWITCH CONDITION, LIFT FRAME – Haas Mill Haas Alarm Description: The pallet changer lift frame switches indicate that the pallet changer lift frame is up and down…