Centroid Alarms
Centroid Alarms, Errors Messages
Centroid Alarm 408 Programmed action time expired
Centroid Alarm 408 Programmed action time expired Cause & Effect M103 time expired before M104 encountered. Job cancelled. Action Find out why timer expired before specified action was completed.
Centroid Alarm 407 limit (#1) tripped
Centroid Alarm 407 limit (#1) tripped Cause & Effect MPU11 stopped with limit switch tripped. Job cancelled. Action Clear limit switch
Centroid Alarm 406 Emergency Stop detected
Centroid Alarm 406 Emergency Stop detected Cause & Effect MPU11 stopped with no fault bits set. Job cancelled. Action Release Estop
Centroid Alarm 405 Lubricant level low
Centroid Alarm 405 Lubricant level low Cause & Effect MPU11 stopped with low lube fault bit set. Current job will finish but nothing will work after that. Action Add lube…
Centroid Alarm 404 Spindle drive fault detected
Centroid Alarm 404 Spindle drive fault detected Cause & Effect MPU11 stopped with spindle drive fault bit set. Job cancelled. Action Check inverter for fault or reset spindle contactor OCR,…
Centroid Alarm 401 PLC failure detected
Centroid Alarm 401 PLC failure detected Cause & Effect MPU11 stopped with PLC failure bit set. Job cancelled. Action Check PLC fibers and PLC logic power.
Centroid Alarm 346 Waiting for spindle direction
Centroid Alarm 346 Waiting for spindle direction Cause & Effect Job progress is paused until the spindle turns the commanded direction.
Centroid Alarm 345 Waiting for spindle to get up to speed
Centroid Alarm 345 Waiting for spindle to get up to speed Cause & Effect Job progress is paused until the actual spindle speed reaches the threshold percentage of the commanded…
Centroid Alarm 344 Feedrate modified due to spindle
Centroid Alarm 344 Feedrate modified due to spindle Cause & Effect The effective feedrate has been lowered because the spindle is spinning slower than the threshold percentage of the commanded…
Centroid Alarm 343 Waiting for stop reason reset
Centroid Alarm 343 Waiting for stop reason reset Cause & Effect PC is waiting for the MPU11 to reset the stop reason (as part of the PC/MPU11 communications handshake)
Centroid Alarm 342 Waiting for motion to stop
Centroid Alarm 342 Waiting for motion to stop Cause & Effect PC is waiting for the MPU11 to complete motion
Centroid Alarm 341 Probing Cycle Finished
Centroid Alarm 341 Probing Cycle Finished Cause & Effect A probing cycle ran to completion
Centroid Alarm 340 Limit (#__) cleared
Centroid Alarm 340 Limit (#__) cleared Cause & Effect A previously tripped limit switch is now in the “untripped” position
Centroid Alarm 339 Jogging…
Centroid Alarm 339 Jogging… Cause & Effect An axis jog key is pressed and machine is moving the corresponding axis
Centroid Alarm 338 Job Cancelled
Centroid Alarm 338 Job Cancelled Cause & Effect ESC or CYCLE CANCEL pressed during job run
Centroid Alarm 337 Digitize complete
Centroid Alarm 337 Digitize complete Cause & Effect A digitizing routine ran to completion
Centroid Alarm 336 Digitize cancelled
Centroid Alarm 336 Digitize cancelled Cause & Effect ESC or CYCLE CANCEL pressed during digitizing
Centroid Alarm 335 Emergency Stop Released
Centroid Alarm 335 Emergency Stop Released Cause & Effect Emergency Stop Button has been released
Centroid Alarm 334 Locating position to resume job…
Centroid Alarm 334 Locating position to resume job… Cause & Effect Run/Search is locating the job continuation point in the program
Centroid Alarm 332 Search Failed
Centroid Alarm 332 Search Failed Cause & Effect Run/Search was unable to find the requested G-code line
Centroid Alarm 331 Threading error: job cancelled
Centroid Alarm 331 Threading error: job cancelled Cause & Effect The programmed threading move will cause an axis to exceed its maximum rate.
Centroid Alarm 330 Canned cycle error: job cancelled
Centroid Alarm 330 Canned cycle error: job cancelled Cause & Effect job was cancelled because of a canned cycle error
Centroid Alarm 329 Invalid parameter: job cancelled
Centroid Alarm 329 Invalid parameter: job cancelled Cause & Effect job was cancelled because of an invalid parameter
Centroid Alarm 328 Cutter comp error: job cancelled
Centroid Alarm 328 Cutter comp error: job cancelled Cause & Effect job was cancelled because of a cutter comp error
Centroid Alarm 327 Fault: job cancelled
Centroid Alarm 327 Fault: job cancelled Cause & Effect job was cancelled because of a fault
Centroid Alarm 326 Fault: probing cancelled
Centroid Alarm 326 Fault: probing cancelled Cause & Effect probing was cancelled because of a fault
Centroid Alarm 325 Limit: job cancelled
Centroid Alarm 325 Limit: job cancelled Cause & Effect job was cancelled because of a limit error
Centroid Alarm 324 Limit: probing cancelled
Centroid Alarm 324 Limit: probing cancelled Cause & Effect probing was cancelled because of a limit error
Centroid Alarm 323 Stall: job cancelled
Centroid Alarm 323 Stall: job cancelled Cause & Effect job was cancelled because of a stall
Centroid Alarm 322 Stall: probing cancelled
Centroid Alarm 322 Stall: probing cancelled Cause & Effect probing was cancelled because of a stall
Centroid Alarm 320 Probe stuck
Centroid Alarm 320 Probe stuck Cause & Effect probe is stuck, or probe hit an object when it wasn’t expecting contact.
Centroid Alarm 319 Probing cycle cancelled
Centroid Alarm 319 Probing cycle cancelled Cause & Effect probing cycle was cancelled
Centroid Alarm 318 Operator Abort probing cancelled
Centroid Alarm 318 Operator Abort probing cancelled Cause & Effect ESC or CYCLE CANCEL pressed while doing a probing move
Centroid Alarm 317 Waiting for automatic tool change
Centroid Alarm 317 Waiting for automatic tool change Cause & Effect cnctch.mac executing
Centroid Alarm 315 Searching…
Centroid Alarm 315 Searching… Cause & Effect Run/search in progress