Centroid Alarms

Centroid Alarms, Errors Messages

Centroid Alarm 408 Programmed action time expired

Centroid Alarm 408 Programmed action time expired Cause & Effect M103 time expired before M104 encountered. Job cancelled. Action Find out why timer expired before specified action was completed.

Centroid Alarm 407 limit (#1) tripped

Centroid Alarm 407 limit (#1) tripped Cause & Effect MPU11 stopped with limit switch tripped. Job cancelled. Action Clear limit switch

Centroid Alarm 406 Emergency Stop detected

Centroid Alarm 406 Emergency Stop detected Cause & Effect MPU11 stopped with no fault bits set. Job cancelled. Action Release Estop

Centroid Alarm 405 Lubricant level low

Centroid Alarm 405 Lubricant level low Cause & Effect MPU11 stopped with low lube fault bit set. Current job will finish but nothing will work after that. Action Add lube…

Centroid Alarm 404 Spindle drive fault detected

Centroid Alarm 404 Spindle drive fault detected Cause & Effect MPU11 stopped with spindle drive fault bit set. Job cancelled. Action Check inverter for fault or reset spindle contactor OCR,…

Centroid Alarm 401 PLC failure detected

Centroid Alarm 401 PLC failure detected Cause & Effect MPU11 stopped with PLC failure bit set. Job cancelled. Action Check PLC fibers and PLC logic power.

Centroid Alarm 346 Waiting for spindle direction

Centroid Alarm 346 Waiting for spindle direction Cause & Effect Job progress is paused until the spindle turns the commanded direction.

Centroid Alarm 345 Waiting for spindle to get up to speed

Centroid Alarm 345 Waiting for spindle to get up to speed Cause & Effect Job progress is paused until the actual spindle speed reaches the threshold percentage of the commanded…

Centroid Alarm 344 Feedrate modified due to spindle

Centroid Alarm 344 Feedrate modified due to spindle Cause & Effect The effective feedrate has been lowered because the spindle is spinning slower than the threshold percentage of the commanded…

Centroid Alarm 343 Waiting for stop reason reset

Centroid Alarm 343 Waiting for stop reason reset Cause & Effect PC is waiting for the MPU11 to reset the stop reason (as part of the PC/MPU11 communications handshake)

Centroid Alarm 342 Waiting for motion to stop

Centroid Alarm 342 Waiting for motion to stop Cause & Effect PC is waiting for the MPU11 to complete motion

Centroid Alarm 341 Probing Cycle Finished

Centroid Alarm 341 Probing Cycle Finished Cause & Effect A probing cycle ran to completion

Centroid Alarm 340 Limit (#__) cleared

Centroid Alarm 340 Limit (#__) cleared Cause & Effect A previously tripped limit switch is now in the “untripped” position

Centroid Alarm 339 Jogging…

Centroid Alarm 339 Jogging… Cause & Effect An axis jog key is pressed and machine is moving the corresponding axis

Centroid Alarm 338 Job Cancelled

Centroid Alarm 338 Job Cancelled Cause & Effect ESC or CYCLE CANCEL pressed during job run

Centroid Alarm 337 Digitize complete

Centroid Alarm 337 Digitize complete Cause & Effect A digitizing routine ran to completion

Centroid Alarm 336 Digitize cancelled

Centroid Alarm 336 Digitize cancelled Cause & Effect ESC or CYCLE CANCEL pressed during digitizing

Centroid Alarm 335 Emergency Stop Released

Centroid Alarm 335 Emergency Stop Released Cause & Effect Emergency Stop Button has been released

Centroid Alarm 334 Locating position to resume job…

Centroid Alarm 334 Locating position to resume job… Cause & Effect Run/Search is locating the job continuation point in the program

Centroid Alarm 332 Search Failed

Centroid Alarm 332 Search Failed Cause & Effect Run/Search was unable to find the requested G-code line

Centroid Alarm 331 Threading error: job cancelled

Centroid Alarm 331 Threading error: job cancelled Cause & Effect The programmed threading move will cause an axis to exceed its maximum rate.

Centroid Alarm 330 Canned cycle error: job cancelled

Centroid Alarm 330 Canned cycle error: job cancelled Cause & Effect job was cancelled because of a canned cycle error

Centroid Alarm 329 Invalid parameter: job cancelled

Centroid Alarm 329 Invalid parameter: job cancelled Cause & Effect job was cancelled because of an invalid parameter

Centroid Alarm 328 Cutter comp error: job cancelled

Centroid Alarm 328 Cutter comp error: job cancelled Cause & Effect job was cancelled because of a cutter comp error

Centroid Alarm 327 Fault: job cancelled

Centroid Alarm 327 Fault: job cancelled Cause & Effect job was cancelled because of a fault

Centroid Alarm 326 Fault: probing cancelled

Centroid Alarm 326 Fault: probing cancelled Cause & Effect probing was cancelled because of a fault

Centroid Alarm 325 Limit: job cancelled

Centroid Alarm 325 Limit: job cancelled Cause & Effect job was cancelled because of a limit error

Centroid Alarm 324 Limit: probing cancelled

Centroid Alarm 324 Limit: probing cancelled Cause & Effect probing was cancelled because of a limit error

Centroid Alarm 323 Stall: job cancelled

Centroid Alarm 323 Stall: job cancelled Cause & Effect job was cancelled because of a stall

Centroid Alarm 322 Stall: probing cancelled

Centroid Alarm 322 Stall: probing cancelled Cause & Effect probing was cancelled because of a stall

Centroid Alarm 320 Probe stuck

Centroid Alarm 320 Probe stuck Cause & Effect probe is stuck, or probe hit an object when it wasn’t expecting contact.

Centroid Alarm 319 Probing cycle cancelled

Centroid Alarm 319 Probing cycle cancelled Cause & Effect probing cycle was cancelled

Centroid Alarm 318 Operator Abort probing cancelled

Centroid Alarm 318 Operator Abort probing cancelled Cause & Effect ESC or CYCLE CANCEL pressed while doing a probing move

Centroid Alarm 317 Waiting for automatic tool change

Centroid Alarm 317 Waiting for automatic tool change Cause & Effect cnctch.mac executing

Centroid Alarm 315 Searching…

Centroid Alarm 315 Searching… Cause & Effect Run/search in progress